The MTL831C EATON analog transmitter is mainly used to convert process measurement signals into standard electrical signals that can be received by the control system.
Features:
•Save installation time,space,and weight
Quickly highlight issues with the status reporting system
•Use sensor fault detection and secure driver protection processes
Connect directly to the host system through serial data output
•Through Modbus®Communication to the controller for analog input
The MTL831C analog transmitter can transmit many hazardous area input signals to safe areas through a data highway composed of single shielded twisted pair cables.It is essentially safe,so it can be installed in Zone 0 hazardous areas or hazardous locations.MTL831C can monitor up to 16 inputs from THC or millivolt power sources,or 2,3,or 4 wire RTDs or potentiometers.Based on different applications,cables,and(noise)environments,a data highway is provided that can transmit signals and electricity over a distance of up to 2 kilometers.It is strongly recommended to use shielded twisted pair cables.At the other end of the data highway,the MTL838C receiver converts the information transmitted from MTL831C.One or two MTL831Cs can be connected to one MTL838C.MTL838C provides input*Modbus®Serial data output representation and status information.When the MTL831C transmitter is installed in a hazardous area,the data highway must be protected by an MTL5553/MTL5053 isolator/power supply installed in a safe area.
With Modbus®The output MTL830C analog multiplexer system provides a cost-effective alternative to single loop isolation.By communicating the inputs of multiple hazardous area sensors on a twisted pair data highway,the cost of installation and wiring has been reduced by 50%.Further savings can be achieved by reducing the number of inputs to the host,cabinet space,and weight.Analog transmitters installed in hazardous areas support thermocouples,RTDs,potentiometers,and mV analog inputs.Compatible secure area receiver provides serial Modbus®Output,used for feeding to the host PLC,PC,or DCS controller.There are two different models of transmitters,MTL831C with fixed screw terminals and MTL831C-PS with pluggable screw terminals(recommended for applications that require regular maintenance).
application area
The MTL831C EATON analog transmitter is mainly used in various industrial sites to convert process measurement signals and provide reliable input signals for automatic control systems.
POLYOL 10%,POLYOLMER POLYOL 10%, POLYOLMER 10%, POLYMERIC POLYOL 10%, POLYMERIC 10%, WANOL F3110P, KE-1990, PPG-3600, PPG 3600, HL-106, ARCOL-1905,LPOP-2010
POLYOL 15%, POLYOLMER POLYOL 15%, POLYOLMER 15%, POLYMERIC POLYOL 15%, POLYMERIC 15%, WANOL F3115P, PPG-3601, PPG 3601, Y-1537, HL-109,LPOP-2015
POLYOL 25%, POLYOLMER POLYOL 25%, POLYOLMER 25%, POLYMERIC POLYOL 25%, POLYMERIC 25%, WANOL F3125P, KE-1950, PPG-3602, PPG 3602, Y-1564, HL-108, ARCOL-1366, LPOP-2025
POLYOL 45%, POLYOLMER POLYOL 45%, POLYOLMER 45%, POLYMERIC POLYOL 45%, POLYMERIC 45%, WANOL F3145P, WANOL F3148P, CS-743, Y-7930, V-3943A, HS-100, LH-50, LH-100, LH-200, LUPRANOL-4600, LHS-50, LHS-100
WANOL POP2045, WANOL POP2140, WANOL POP3630, WANOL POP3628, WANOL F3135, WANOL F3140, WANOL F3150, WANOL F3160, WANOL F3180, KE-878N, HL-400, INOVOL, PURANOL, WANOL, LUPRANOL, ARCOL
TDI:
Tolulene diisocyanates, TDI 80/20, WANHUA TDI, BASF TDI, HANWHA TDI, COVESTRO TDI, DAHUA TDI, JULI TDI, Lupranate TDI-80, WANATE TDI-80, WANNATE PM-200, WANNATE PM-100, 44V20L, M20S, 5005, Tolulene diisocyanates 80/20, Desmodur T80/20, Desmodur T80
Reviews
There are no reviews yet.