BENTLY 350015
Regarding the parameter specifications for BENTLY 3500/15 127610-01:
Power input: 100-240 VAC, 50/60 Hz, 2 A
Power output: 24 VDC, 5.5 A
Size: 3.35×9.5×10.25 inches (85x242x260 mm)
Weight: 4.0 pounds (1.8 kilograms)
Working temperature: 0 ℃ to 60 ℃
DC output stability: ± 1%
Overload protection: 120% rated current, automatic protection
Short circuit protection: automatic protection
Input and output insulation resistance: 500 VDC, greater than 10 MQ
The BENTLY 3500/15 127610-01 power card has a stable and reliable power output, which can meet the power requirements of sensors and monitoring equipment in various vibration monitoring systems. It also has overload protection and short circuit protection
Road protection function to ensure the safe operation of equipment
EBARA HV-8 8″CRYO TURBO VACUUM PUMP
HP 8157A OPTICAL ATTENUATOR 1300/1550nm
STRYKER ENDOSCOPY X6000(REF 220-185-000)LIGHT SOURCE
EDWARDS E2M5 DUAL STAGE ROTARY VANE VACUUM PUMP
Adept Tech 10332-00714 040 VME PROCESSOR BOARD ROBOT
STRYKER ENDOSCOPY Q5000(REF 220-180-000)LIGHT SOURCE
ADEPT PA-4 30336-31000R ROBOT CONTROLLER CHASSIS
BENTLY 3500/15 127610-01 Technical guidance for on-site use:
Installation location: The power card should be installed in an electrical cabinet with a protection level of IP20 or higher, avoiding use in damp, high temperature, high voltage, and other environments to avoid affecting the performance and lifespan of the power supply.
Connection method: Before connecting the power card, turn off the power supply and confirm that the power supply voltage and output voltage meet the requirements. When wiring, reliable cables and connectors should be used to ensure reliable contact
Correct wiring to avoid equipment malfunctions caused by wiring issues.
Anti static: When operating the power card, avoid static interference and use anti-static devices such as static bracelets to ensure safety and reliability.
Maintenance: Regularly inspect the wiring and connectors of the power card, remove dust and impurities from the circuit board, and maintain the cleanliness and good heat dissipation conditions of the power card. If a malfunction is found, it should be stopped for inspection in a timely manner to avoid
Avoid serious consequences caused by the expansion of the fault.
Precautions for use: The power card is an important component of the device, and attention should be paid to avoiding collisions, falls, or strong vibrations to avoid damaging the power card or causing unstable power output.