GE Multilin IC693MDL742 Modbus Master/Slave Interface Module
Parameters, Specifications, Dimensions, Weight, Series, Features, and Function
Parameters:
- Communication Protocol: Modbus RTU or Modbus TCP/IP
- Baud Rate: 9600, 19200, 38400, or 57600 baud
- Parity: None, Even, or Odd
- Stop Bits: 1 or 2
- Data Bits: 8
- Slave ID: 1-255 (Modbus slave mode only)
- Modbus Register Mapping: Modbus function code 3 (Read Holding Registers), function code 16 (Write Holding Registers), function code 4 (Read Input Registers), and function code 17 (Write Input Registers)
- Power Supply: 24 VDC or 120 VAC
- Power Consumption: Approximately 25 W
- Operating Temperature: -40°C to +70°C (-40°F to +158°F)
- Storage Temperature: -40°C to +85°C (-40°F to +185°F)
- Humidity: 5% to 95% RH non-condensing
- Vibration: 0.5 g RMS, 5 to 500 Hz
- Shock: 5 g, 22 ms half-sine pulse
- EMC: Meets IEC 61000-4-2, IEC 61000-4-3, and IEC 61000-4-6 standards
- Safety: Meets UL 508, CSA C22.2 No. 142, and CE standards
Specifications:
- Modbus Master/Slave Interface Module: Allows a Series 90-30 PLC to communicate with Modbus devices
- Modbus Master Mode: The module can act as a Modbus master, polling Modbus slave devices for data
- Modbus Slave Mode: The module can act as a Modbus slave, responding to Modbus master requests for data
- Supports Modbus Function Codes 3, 4, 16, and 17: Provides flexible data access for a wide range of Modbus devices
- Diagnostic LEDs: Provides status information about the module, including power, communication, and data errors
- Terminal Block Connection: Offers simple connection to Modbus devices and the Series 90-30 PLC
Dimensions:
- Height: 114 mm (4.50 in)
- Width: 165 mm (6.50 in)
- Depth: 22.5 mm (0.89 in)
Weight:
- Approximately 0.4 kg (0.88 lb)
Series:
- IC693 Series I/O Modules
Features:
- Modbus master/slave functionality: Allows the module to act as either a Modbus master or a Modbus slave, providing flexibility for a variety of communication scenarios
- Support for Modbus function codes 3, 4, 16, and 17: Enables data exchange with a wide range of Modbus devices
- Diagnostic LEDs: Provides visual status information about the module’s operation
- Terminal block connection: Offers simple and secure connection to Modbus devices and the Series 90-30 PLC
Function:
The GE Multilin IC693MDL742 Modbus Master/Slave Interface Module is a versatile tool for connecting a Series 90-30 PLC to Modbus devices. It provides a simple and reliable way to exchange data between the PLC and Modbus devices, making it ideal for a variety of applications.
In Modbus master mode, the module can poll Modbus slave devices for data, such as sensor readings or control setpoints. This allows the PLC to gather information from a variety of sources and use it to make control decisions.
In Modbus slave mode, the module can respond to Modbus master requests for data. This allows the PLC to share its data with other devices, such as HMI panels or SCADA systems.
The IC693MDL742’s support for Modbus function codes 3, 4, 16, and 17 ensures compatibility with a wide range of Modbus devices. Its diagnostic LEDs provide valuable status information about the module’s operation, making it easy to troubleshoot any issues. Its terminal block connection offers a secure and reliable way to connect to Modbus devices and the Series 90-30 PLC.
With
IC693MDL742